Description

Features
> Dual guided cantilever and shear beam design for high accuracy
> Compact, lightweight and easy to handle
> Temperature compensation maintains both zero and span from -10 °C to +60 °C (+14 °F to +104 °F)
> Moisture proof
> Can be used for multi-point weighing

Specifications
Rated capacities …………………………………20 kgf, 50 kgf, 100 kgf, 200 kgf, 500 kgf, 1 tf, 2 tf, 5 tf
Rated output ……………………………………….2 mV/V±0.5% (20 kgf, 50 kgf – 1.5 mV/V ± 0.5%)
Maximum safe overload ……………………..200% of rated capacity
Combined error ………………………………….±0.02% of rated output
Creep…………………………………………………..±0.1 %of rated output/hour
Zero balance ………………………………………±2% of rated output
Compensated
temperature range……………………………… -10 °C to 60 °C/14 °F to +104 °F
Recommended
excitation Voltage ………………………………..12 V
Maximum.
excitation voltage …………………………………15 V
Input terminal resistance …………………….Approximately 400 Ω
Output terminal resistance ………………….350 Ω ± 3.5 Ω
Insulation resistance …………………………..Greater than 5000 MΩ at DC50 V
Temperature effect
-Zero ……………………………………………………0.007% of rated output/°C
-Span ………………………………………………….0.002% of rated output/°C Typ.
Cable length ………………………………………3 m/118 inches (1, 2 & 5 t -5 m/197 inches)