Description

Features
> Hermetical sealed stainless steel construction protection from water, moisture and corrosion(IP68)*
> Advanced load design for tanks, hoppers and truck scales
> Compression type

Specifications
Rated capacities……………………………… 10 tf, 20 tf, 30 tf
Rated output ……………………………………..2 mV/V ± 0.1%
Maximum safe overload ……………………200% of R. C.
Combined error …………………………………0.016% of R. O.
Recommended excitation voltage …….DC5 to12 V
Maximum excitation voltage ………………DC15 V
Zero balance …………………………………….±1% of R. O.
Input terminal resistance ………………….800 Ω ± 80 Ω
Output terminal resistance ……………….2200 ± 10 Ω
Insulation resistance ………………………..Greater than 5000 MΩ/DC50 V
Operating temperature……………………. -20 °C to 60 °C
Temperature effect
Zero …………………………………………………..0.019% of R.O./10 Typ.
Span …………………………………………………0.010% of Load/10 Typ.
Cable diameter/Length …………………….φ8/12 m
Dustproof/Waterproof ……………………….IP68

*The LCC11 provides for IP68 enclosure rating with greater than 100 hours protection at 1.5 m immersion.